OC-F08 Ammonia NH3 Fixed Gas Detector Independent Air Chamber Replace Sensor Without Recalibration for Cement Plant

OC-F08 fixed ammonia NH3 gas detector with independent air chamber. Replace sensor without recalibration, explosion-proof IP66, for real-time ammonia concentration monitoring in various industrial environments, supports 4-20mA & RS485 output.

Get A Quote
Contact Us

Description

This fixed ammonia NH3 gas detector OC-F08 is a professional industrial toxic gas transmitter for general industrial gas safety monitoring. With independent air chamber design, it allows quick sensor replacement without recalibration, effectively reducing maintenance workload and operation cost.

It adopts high-precision electrochemical sensor to achieve 24-hour continuous online monitoring of ammonia concentration. Built with explosion-proof construction and IP66 protection grade, it supports audible-visual alarm and relay output. Multiple signal outputs including 4-20mA and RS485 are optional, compatible with PLC, DCS and alarm host systems. Diffusion and pump-suction sampling modes are selectable, delivering stable and reliable detection performance in diverse complex industrial environments.

Features:

  • 4-20mA standard analog signal and RS485 digital signal output, 200~ 1000HZsignal output, relay output (optional);
  • Intelligent sensor, modular design, easy maintenance
  • Display the gas concentration in ppm, %LEL, %vol and mg/m3 is selectable;
  • LCD screen displaying the gas concentration, gas type, unit, instrument status etc.
  • Independent  air  chamber,  the  sensor  is  not  required  to  replace  the  sensor  calibration, automatic identification of key parameters of the sensor;
  • Infrared remote control operation, avoid cover opening operation in dangerous situations.
  • With the  16bit ADC  acquisition  chip,  designed  with four-layer  circuit  board,  so with  high anti-interference ability;
  • With the Ex-proof certificate, the Ex-proof grade is Exd II CT6.

Technical Parameter:

Detection Gas Ammonia (NH3)
Sensor Type Electrochemical sensor
Detecting Range 0-20ppm、50ppm、100ppm、200ppm、500ppm、1000ppm、2000ppm、5000ppm、10000ppm、50000ppm or customized
Resolution 0.01ppm, 0.1ppm, 1ppm
Sampling Diffusion or pump-suction, circulation selectable
Precision ≤±3%F.S
Repeatability ≤±2%
Zero drift ≤±1%(F.S/year)
Sensor Life 2~3years

(Catalytic combustion, Electrochemical, Semiconductor)

3~5 years(PID, Infrared)

Response Time (T90) ≤30s(combustible gas)
Alarming mode Audible-visual alarm, relay output alarm
Working Temperature -20℃~50℃ (Toxic gas)

-40℃~70℃ (Combustible gas)

Or Customized for special demands

Working Humidity 10%~95%RH (non-condensing), if >90%RH, can add the filter
Working Pressure 86kPa~106kPa
Working Voltage 24V DC (Normal operating voltage range: 10~30VDC)
Power consumption <1.5W (Toxic gas) ; <2.5W (Combustible gas)
Output Signals (Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc;

(Optional) Four-wire system RS485 digital signal output;

(Optional) Frequency signal 200~1000Hz output;

Two-level relay output:220VAC 0.5A, 5VDC 0.5A

Two sets of passive relays (24VDC 2A)

Installation Means Wall mounted, Pipe type (Thread:M40*1.5 )
Main material Shell (Die casting aluminum) , Air chamber (Hard alumina)
Explosion-proof Index Exd IIC T6 Gb(Combustible gas) Exd ib IIC T6 Gb(Toxic gas)
Protection Grade IP66
Electrical Interface 3/4″NPT(Female Screw)、1/2″NPT(Female Screw)
Transmit Distance ≤2000m (If more than 2000m, can add the repeater.)
Dimension 185 mm×137.2 mm×90.7mm(L×W×H)
Weight About 1.6Kg
Standards GB15322.1-2003, GB3836.1-2010, GB3836.2-2010, GB3836.4-2010, GB12358-2006
Warranty 12months
Certificate CNEx, CE, RoHS

Remark: If you need gas or measuring range not listed on the above, pls send us your details requirments for further discussion.

Application Scenarios

  • Industrial ammonia leakage safety monitoring
  • Flue gas denitrification ammonia slip monitoring
  • Chemical production workshops
  • Ammonia storage and distribution areas
  • Wastewater treatment facilities
  • Fertilizer manufacturing plants
  • Refrigeration systems with ammonia medium
  • Livestock and poultry breeding sites

Company profile

We Henan Oceanus is located in Henan, a land with a long history and profound cultural heritage, has been dedicated to the research, development, production, and sales of Gas detection system and Environment equipments since its establishment. With exquisite technology and outstanding quality, we have won widespread recognition in the global marketing.

 

1

Manufacturing & Quality Control

Every Detail Matters. Every Product Deserves Care.

At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.

  • Power‑on test

Each product undergoes visual and functional checks to verify component assembly, wiring connections, display operation and basic functionality before delivery.

d74fae67ea643cea444190c537a7a469_720.jpg

  • Product Aging Test

Aging tests are conducted on applicable products to evaluate operational stability and identify potential issues during continuous operation.

5a81fef44ec129de78df74213763c098_720.jpg

  • Calibration & Performance Verification

Measuring performance is verified using appropriate reference equipment and standard gases, where applicable, to help ensure reliable measurement results.

image.png

  • Final Inspection Before Delivery

Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.

1793949240107651.jpg

Every unit is assembled on our own production line, then put through our in-house quality control before it ships. Each instrument undergoes a full inspection, a burn-in aging test and precision calibration, and is finally standardized against reference gases to verify accuracy at the point of delivery. Nothing leaves our factory untested. We also welcome OEM and ODM projects, and every product is backed by our warranty support. Controlling the process from assembly to final calibration is how we keep quality consistent and respond quickly to custom requirements.

Our After-sales service:

1. OEM service for LOGO, model, Technical Parameters, Operation manual, etc.

2. Free calibration service and provide calibration methods.

3. One year warranty and lifetime warranty

If you need more details of the Air quality monitor station, welcome to contact us:

No. 2206, Wenhua Chanye Building Block B, No. 77, Shangding Road, Zhengzhou Area, Henan Pilot Free Trade Zone

Email: info@china-oceanus.com

Telephone: +86 0371 60998169

Mobile/Whatsapp: +86 15981942832

Mobile/Whatsapp: +86 13673683950

Scroll to Top