OC-HY128B Color Screen Multi-Function Sound Level Meter | Class 2 Octave & 1/3 Octave Noise Analyzer

OC-HY128B digital sound level meter with 2.8-inch color screen, 7 working modes, Class 2 accuracy, 20–144 dB(A) range, 1/1 and 1/3 octave analysis, 24h continuous monitoring, 32 GB storage. Suitable for environmental noise, occupational health and product noise testing.

Get A Quote
Contact Us

OC-HY128B Color Screen Multi-Function Sound Level Meter | Class 2 Octave & 1/3 Octave Noise Analyzer

Digital Class 2 Sound Level Meter with Octave Analysis, 24h Monitoring and Personal Exposure Measurement

Description:

The OC-HY128B is a fully digital multi-function sound level meter built around a 2.8-inch color display. It measures frequency-weighted and time-weighted sound pressure level, equivalent continuous sound level, exposure sound level and statistical sound level for acoustic evaluation of different noise sources.

Seven working modes are selectable: integral average, parallel measurement, statistical analysis, 24-hour measurement, 1/1 octave analysis, 1/3 octave analysis and indoor noise measurement. A dedicated low-frequency A-weighting mode is provided for secondary radiation noise measurement, which is important for building acoustics and low-frequency environmental complaints.

The instrument runs on a 3.7 V 6000 mAh lithium battery and can also work while charging from a power bank — practical for 24-hour continuous environmental noise surveys without mains power. Measurements can be stored on a 32 GB TF card (up to 64 GB), printed through the DB9 port and transferred to a PC through the USB interface.

The OC-HY128B series is available in several configuration levels (see model table below), so buyers can choose only the analysis functions their projects require — from basic integral/statistical measurement to full 1/1 and 1/3 octave band analysis.


Applications
  • Environmental Noise Monitoring: Urban acoustic function zones, construction site boundaries, roads and traffic corridors, industrial plant perimeters.
  • Occupational Health & Industrial Hygiene: Workplace noise exposure assessment, hearing-conservation programmes, personal daily exposure evaluation.
  • 24-Hour Continuous Surveys: Long-duration unattended noise logging for EIA baseline studies and compliance reports.
  • Building & Low-Frequency Acoustics: Secondary radiation noise measurement from building services, ventilation and low-frequency sources.
  • Indoor Noise Assessment: Classrooms, offices, hospitals, residential interiors.
  • Product & Equipment Noise Testing: Machinery, HVAC equipment, household appliances and vehicle component noise measurement in laboratory or factory environments.
  • Machinery Manufacturing & Quality Control: Production-line noise inspection and acceptance testing.

Optional Type: 

Type No.: Class level Integral average Statistical analytical Integral parallel 24h Test Indoor Noise 1/1

OCT

1/3

OCT

HY128B-Basic 2 √ √ √        
HY128B-1 2 √ √ √ √      
HY128B-2 2 √ √ √ √ √    
HY128B-3 2 √ √ √ √ √ √  
HY128B-4 2 √ √ √ √ √ √ √
HY128B-5 2 √ √        

Technical Parameter:

Main measurement indicators: LXY(X=A、C or Z, Y=F、S or I), LXYmax, LXYmin, LCpeak, 1sLeq, Leq, LE, E, D, Laeq,8hn, LN(N=1~99, choose 5), SD, Lh, Ld, Le, Ln, Ldn, Lden, LAv, TWA, LeqC-A, etc.
Frequency range: 10Hz~12.5kHz (Class2)
Time weighting: F,S,I
Frequency weighting: A,C,Z
Low-frequency 16Hz~200Hz(for secondary radiation noise measurement)
Detection range: A: 20dB~144dB, C: 30dB~144dB, Z: 40dB~144dB, C-weighted peak sound level 60dB~147dB
Display: 2.8inch OLCD color display screen, Resolution 240*320
Octave filter: 1/1 Octave filter: 8 Hz, 16 Hz, 31.5 Hz, 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz, 4kHz, 8 kHz and 16 kHz.
1/3 Octave filter: 6.3 Hz, 8 Hz, 10 Hz, 12.5 Hz, 16 Hz,20 Hz, 25 Hz,31.5 Hz,40 Hz,50 Hz,63 Hz,80Hz,100Hz,125 Hz, 160 Hz, 200Hz, 250 Hz, 315 Hz, 400 Hz, 500 Hz, 630 Hz, 800 Hz, 1 kHz, 1.25 kHz, 1.6 kHz, 2 kHz, 2.5 kHz, 3.15 kHz, 4 kHz, 5 kHz, 6.3 kHz, 8 kHz, 10 kHz, 12.5 kHz, 16 kHz and 20 kHz
Analog output: 1) The output jack is a 3.5mm dual-channel headphone jack.

2)DC output: The output voltage is about 15mV/dB, and the range is 300mV~2160mV.

3)AC output: The output has a linear relationship with the measured signal, and the root mean square value of the maximum AC output voltage does not exceed 3V.

Storage 32G TF card, Max 64G
Data output DB9 male connector (pin type) is used for printing, and USB B type socket is used for data communication
Power supply 3.7v 6000mAh Li-battery, or power bank for 24h monitoring
Size/Weight 250*78*30mm/360g
Working temperature -20℃~50℃

After-sales Service
  • Pre-sales consultation: working-mode and model selection guidance based on measurement task (environmental, occupational or product noise).
  • Product customization: model configuration, branded enclosure and packaging options for distributors and OEM projects.
  • Factory calibration: each unit is functionally tested and acoustically checked before shipment; calibration certificate available on request.
  • Warranty: 12-month warranty covering the main unit; rechargeable battery, microphone and accessories handled as consumables.
  • Technical support: operation manual, PC software and communication guidance; remote troubleshooting support.
  • Spare parts & re-calibration: microphone capsules, windscreens, batteries and calibration service available throughout the product life cycle.

Manufacturer Quality & Reliability

Every Detail Matters. Every Product Deserves Care.

At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.

Product Inspection → Product Aging Test → Calibration & Performance Verification → Final Inspection Before Delivery

Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.

Inquiry Section

Get Configuration Recommendation and Quotation

Tell us the measurement purpose, required working modes (octave analysis, 24h test, indoor noise) and quantity. We will recommend the matching model and offer a quotation.

Email: info@china-oceanus.com

Telephone: +86 0371 60998169

Mobile/Whatsapp: +86 15981942832

Mobile/Whatsapp: +86 13673683950