OC‑F08 Fixed LPG Gas Detector
Explosion‑Proof Wall‑Mount LPG Combustible Gas Transmitter For 24/7 Industrial Leakage Monitoring

✅ Request A Quote Share your site and gas‑monitoring requirements, we reply you within 24 working hours.
Overview
The OC‑F08 fixed LPG gas detector adopts imported catalytic‑combustion sensor and ultra‑low‑power 32‑bit micro‑processor hardware platform, delivering stable, fast‑response continuous monitoring for liquefied petroleum gas(LPG) leakage in hazardous industrial zones.
This transmitter supports diffusion or optional pump‑suction sampling. Multiple industry‑standard signal outputs including 4‑20 mA analog, RS485 digital, frequency signal and relay alarm output allow seamless integration with PLC, DCS, local alarm controllers and industrial computers, realizing remote real‑time observation, over‑limit alarm and historical‑data recording.
With Ex d IIC T6 Gb flame‑proof certification and IP66 die‑cast aluminum housing, it supports long‑term unattended field‑site operation. Infrared remote‑control operation enables full parameter configuration without opening enclosure in explosive‑risk locations. Modular intelligent sensor design simplifies maintenance and sensor‑replacement work on‑site.
Besides LPG, this OC‑F08 platform supports swapping sensors to detect various combustible and toxic gases, covering ammonia, chlorine, hydrogen, formaldehyde, oxygen, hydrogen sulfide, carbon monoxide, methane, propane, carbon‑dioxide and more.
Main Applications
‑ LPG filling stations & storage yards: Real‑time LPG leakage early‑warning for tank‑area and pipeline zones.
‑ Petrochemical & Refineries: Workshop and storage‑area combustible‑gas safety supervision.
‑ Gas boiler houses & industrial kitchens: LPG leak‑detection for fuel‑consuming facilities.
‑ Chemical & Pharmaceutical Plants: Hazard‑zone flammable‑gas continuous monitoring.
‑ Mining & Coking Plants: Plant‑boundary combustible‑gas safety surveillance.
‑ Sewage‑treatment & municipal projects: Hazard‑gas monitoring for gas‑generation tank areas.
‑ Marine & On‑board installations: Cabin LPG‑risk monitoring for ship projects.

Core Advantages & Key Features
‑ Specialized LPG monitoring: Catalytic‑combustion sensor for LPG, measuring range 0‑100%LEL; diffusion sampling as standard, pump‑suction sampling optional.
‑ Rich multi‑interface output: 4‑20 mA three‑wire analog signal, RS485 Modbus digital signal, 200‑1000 Hz frequency signal; dual‑channel relay alarm output optional for linkage with exhaust fan & alarm lamp.
‑ Modular intelligent sensor: Independent air‑chamber structure; sensor auto‑identifies key parameters; no full‑unit re‑calibration after sensor replacement for easy maintenance.
‑ Infrared remote‑controller setting: Complete configuration without opening housing inside classified hazardous explosion areas.
‑ High‑anti‑interference hardware: 16‑bit ADC chip and four‑layer‑PCB circuit design, stable for complex industrial electromagnetic environment.
‑ Local LCD display: Shows gas concentration, gas type, engineering unit and instrument working‑status; ppm / %LEL / %vol / mg/m³ unit selectable.
‑ Robust explosion‑proof enclosure: Ex d IIC T6 Gb flame‑proof grade, IP66 die‑cast‑aluminum housing, fit for indoor & outdoor harsh industrial sites.
‑ Wide environmental adaptability: ‑40 ℃ ~ +70 ℃ working temp for combustible‑gas version; high‑humidity filter accessory available for damp locations.
Technical Specifications
| Item | OC‑F08 LPG Version Specification |
|---|---|
| Detected Gas | LPG(Liquefied Petroleum Gas) |
| Sensor Type | Catalytic combustion sensor |
| Measuring Range | 0‑100%LEL |
| Resolution | 1%LEL |
| Sampling Mode | Diffusion sampling; pump‑suction circulation optional |
| Precision | ≤ ±3 %FS |
| Repeatability | ≤ ±2 %FS |
| Zero Drift | ≤ ±1 %FS / year |
| Sensor Service Life | 2‑3 years (catalytic‑combustion) |
| T90 Response Time | ≤ 30 s |
| Alarm Mode | Audible‑visual alarm, relay‑output alarm |
| Working Temperature | ‑40 ℃ ~ +70 ℃ (combustible‑gas configuration) |
| Working Humidity | 10‑95 %RH (non‑condensing); filter for high‑humidity environment optional |
| Working Pressure | 86 kPa ~ 106 kPa |
| Working Voltage | 24 V DC (10‑30 VDC acceptable) |
| Power Consumption | <2.5 W (combustible‑gas) |
| Signal Output | Standard: 4‑20 mA three‑wire signal;
Optional: RS485,200‑1000Hz frequency, two‑group relay output |
| Installation | Wall‑mount / Pipe‑thread installation (M40*1.5) |
| Housing Material | Die‑cast‑aluminum housing, hard‑alumina air‑chamber |
| Explosion‑proof Grade | Ex d IIC T6 Gb |
| Protection Grade | IP66 |
| Electrical Thread | 3/4″ NPT(Female),1/2″ NPT(Female) |
| Max Transmission Distance | ≤ 2000 m; signal repeater for longer distance |
| Dimension | 185 × 137.2 × 90.7 mm(L×W×H) |
| Weight | Approx.1.6 kg |
| Compliance Standards | GB15322.1‑2003, GB3836.1‑2010, GB3836.2‑2010, GB3836.4‑2010, GB12358‑2006 |
| Certificates | CNEx, CE, RoHS |
| Warranty | 12‑month warranty for main unit |
Remark: OC‑F08 supports sensor‑swap for many other combustible & toxic gases. Please contact sales for gas‑list, measuring‑range and alarm‑threshold confirmation.
Optional Detectable Gas Reference
| Gas | Detecting Range | Alarm Threshold | Sensor Type |
| NH3 | 0-100 PPM | 25 PPM / 50 PPM | Electrochemical sensor |
| Cl2 | 0-50.0 PPM | 10 PPM / 20 PPM | |
| H2 | 0-1000 PPM | 50 PPM / 100 PPM | |
| CH2O | 0-100 PPM | 25 PPM / 50 PPM | |
| O2 | 0-30.0%vol | 18.5%vol / 23.5%vol | |
| H2S | 0-100 PPM | 10 PPM / 20 PPM | |
| HCl | 0-30.0 PPM | 5.0 PPM / 10.0 PPM | |
| HCN | 0-50.0 PPM | 5.0 PPM / 10.0 PPM | |
| PH3 | 0-20.0 PPM | 0.3 PPM / 0.6 PPM | |
| HF | 0-10.0 PPM | 3.0 PPM / 6.0 PPM | |
| NO | 0-250 PPM | 25 PPM / 50 PPM | |
| CO | 0-500 PPM | 35 PPM / 70 PPM | |
| SO2 | 0-20.0 PPM | 2.0 PPM / 10.0 PPM | |
| ClO2 | 0-50.0 PPM | 0.3 PPM / 0.5 PPM | |
| NO2 | 0-20.0 PPM | 1.0 PPM / 2.0 PPM | |
| C2H4O | 0-100 PPM | 10 PPM / 20 PPM | |
| O3 | 0-20.0 PPM | 5.0 PPM / 10.0 PPM | |
| CH4 | 0-100%LEL | 25%LEL / 50%LEL | Catalytic combustion sensor |
| C3H8 | 0-100%LEL | 25%LEL / 50%LEL | |
| H2 | 0-100%LEL | 25%LEL / 50%LEL | |
| NH3 | 0-100%LEL | 25%LEL / 50%LEL | |
| C2H4O | 0-100%LEL | 25%LEL / 50%LEL | |
| CH3CH3 | 0-100%LEL | 25%LEL / 50%LEL | |
| C2H4 | 0-100%LEL | 25%LEL / 50%LEL | |
| C4H10 | 0-100%LEL | 25%LEL / 50%LEL | |
| C4H8 | 0-100%LEL | 25%LEL / 50%LEL | |
| C7H8 | 0-100%LEL | 25%LEL / 50%LEL | |
| C8H10 | 0-100%LEL | 25%LEL / 50%LEL | |
| CH4O | 0-100%LEL | 25%LEL / 50%LEL | |
| C2H6O | 0-100%LEL | 25%LEL / 50%LEL | |
| C3H4O | 0-100%LEL | 25%LEL / 50%LEL | |
| C2H3Cl | 0-100%LEL | 25%LEL / 50%LEL | |
| C3H9N | 0-100%LEL | 25%LEL / 50%LEL | |
| CH3Br | 0-100%LEL | 25%LEL / 50%LEL | |
| CO2 | 0-5.0%vol | 1.0%vol / 3.0%vol | NDIR infrared sensor
|
| 0-5000ppm | 800 PPM / 1500 PPM | ||
| CH4 | 0-5.0%vol
0-100%vol |
1.0%vol / 3.0%vol
5%vol / 10%vol |

Company Profile
We Henan Oceanus is located in Henan, a land with a long history and profound cultural heritage, has been dedicated to the research, development, production, and sales of Gas detection system and Environment equipment since its establishment. With exquisite technology and outstanding quality, we have won widespread recognition in the global marketing.

Manufacturing & Quality Control
Every Detail Matters. Every Product Deserves Care.
At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.
- Power‑on test
Each product undergoes visual and functional checks to verify component assembly, wiring connections, display operation and basic functionality before delivery.

- Product Aging Test
Aging tests are conducted on applicable products to evaluate operational stability and identify potential issues during continuous operation.

- Calibration & Performance Verification
Measuring performance is verified using appropriate reference equipment and standard gases, where applicable, to help ensure reliable measurement results.

- Final Inspection Before Delivery
Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.

Factory Quality Assurance
Every OC‑F08 unit completes full‑sequence factory inspection before delivery:
- Incoming inspection for sensors, die‑cast‑aluminum housing and circuit‑board assemblies
- Assembly and circuit‑continuity check
- Full‑function power‑on aging test
- Multi‑point calibration for target‑gas channel
- Explosion‑proof safety & appearance inspection
- Final outgoing FQC inspection before packing
Calibration‑test records, CNEx, CE & RoHS certification documents are available upon commercial request.
Inquiry Section
Get Custom‑made Quotation For Your Application
Please tell us target‑gas type, measuring‑range, required signal‑output type, installation‑environment and quantity. Our engineering team will give configuration suggestions and quotation for your industrial‑safety‑monitoring project.
Email: info@china-oceanus.com
Telephone: +86 0371 60998169
Mobile/Whatsapp: +86 15981942832
Mobile/Whatsapp: +86 13673683950