OC‑2000 Portable Multi‑Gas Analyzer | 1‑12 Gases Pump‑suction Explosion‑Proof Gas Detector
OC‑2000 portable pump‑suction multi‑gas detector supports custom 1‑12 gas sensors, Ex ia II C T6 intrinsically‑safe, 100,000 groups data logging, optional high‑temperature sampling probe for petrochemical, environmental spot inspection, confined‑space testing. OEM ODM available. Request quotation.

Overview
The OC‑2000 portable multi‑gas analyzer is an industrial‑grade field gas detection instrument. Built around ultra‑low‑power 32‑bit MCU and high‑precision 24‑bit ADC chip, it adopts mixed‑signal digital‑analog circuit design for stable field‑measurement performance.
Support flexible configuration from 1 up to 12 different gas sensors. Equipped with built‑in high‑flow suction pump, it realizes remote sampling up to 5 meters and works reliably under micro‑negative‑pressure conditions. Two measuring modes: real‑time instantaneous reading and timed‑average‑value measurement, store maximum 100 000 groups of detection records.
Optional accessories include mini on‑board printer, high‑temperature sampling probe, temp‑humidity module, long‑distance wireless transmitter and GPRS remote transmission module. With Ex ia II C T6 intrinsic‑safety explosion‑proof grade and IP65 enclosure, it fits complex on‑site conditions of petrochemical refineries, environmental law‑enforcement spot checks, metallurgy, biopharmaceutical and agricultural‑site investigation.
Main Applications
‑ Petrochemical & Refinery Sites: Equipment leak inspection, process‑gas spot‑sampling analysis
‑ Environmental Enforcement & Testing Agencies: Waste‑gas spot survey, emission screening test, field environmental assessment
‑ Confined‑space Pre‑entry Safety Testing: Tanks, pipelines, reaction‑vessel pre‑detection work
‑ Metallurgy & Chemical Plants: Routine safety patrol and toxic‑gas hazard inspection
‑ Biomedicine & Pharmaceutical Facilities: Workshop atmosphere monitoring
‑ High‑temperature flue‑gas sampling: Match optional high‑temperature sampling probe for furnace‑exhaust spot‑testing

Core Advantages & Key Features
‑ High‑density multi‑sensor expandability: Freely configure 1‑12 gas sensors; support catalytic combustion, electrochemical, infrared (NDIR), PID sensor technologies for different target gases.
‑ Built‑in powerful pump‑suction system: Max sampling distance up to 5 m, stable operation under micro‑negative‑pressure; optimized gas‑chamber structure to protect sensors from pressure impact.
‑ 3.5‑inch industrial color display: Readings available in ppm, %vol, mg/m³ units; automatic self‑diagnosis for sensors, chips and hardware upon power‑on.
‑ Massive local‑data storage: Up to 100 000 groups data records; optional mini‑printer supports manual / auto‑interval print output.
‑ Dual measuring modes: Real‑time measurement and timing‑average‑value measurement to satisfy different field‑test purposes.
‑ Multi‑point automatic sensor calibration: Support up to 6‑point calibration, full‑span temperature compensation; one‑key restore factory‑default parameters.
‑ Complete circuit‑level protection: Over‑charge, over‑voltage, short‑circuit, anti‑static and anti‑magnetic‑interference protection design.
‑ Intrinsic‑safety explosion‑proof Ex ia II C T6, IP65 housing for harsh‑site environment.
‑ Rich optional hardware modules: High‑temperature sampling probe, temperature‑humidity sensor, wireless / GPRS remote‑transmission unit.
‑ OEM & ODM customization: Support sensor‑list adjustment, interface modification, logo & housing customization for system integrators and distributors.
General System Specifications
| Item | OC‑2000 Specification |
|---|---|
| Detectable Gas Types | Combustible gas, O₂, toxic gases, CO₂, TVOC etc. (1‑12 sensors configurable) |
| Sensor Options | Catalytic combustion, Electrochemical, Infrared‑NDIR, PID |
| T90 Response Time | ≤20 s |
| Repeatability | ≤ ±1 % FS |
| Linearity | ≤ ±1 % FS |
| Zero Drift | ≤ ±1 % FS / year |
| Sampling Mode | Built‑in pump‑suction, flow rate 2 L/min; max sampling distance 5 m; adapt micro‑negative‑pressure |
| Working Mode | Real‑time measurement / Timed‑average‑value measurement |
| Data Storage | Max.100 000 groups records; real‑time & timed‑storage |
| Optional mini‑printer; adjustable print interval, auto‑print / manual‑print | |
| Self‑check Function | Battery, screen, sensor & hardware automatic diagnosis |
| Alarm Mode | Audible‑visual dual‑alarm |
| Explosion‑proof Grade | Ex ia II C T6 |
| Protection Grade | IP65 |
| Working Temperature | ‑30 ℃ ~ +60 ℃ |
| Working Humidity | ≤95 %RH (non‑condensing) |
| Working Pressure | ‑30 kPa ~ 100 kPa |
| Power Supply | 6000 mAh rechargeable lithium‑ion battery |
| Dimension(L×W×H) | 230 × 120 × 220 mm |
| Weight | 2.5 kg |
| Optional Accessories | High‑temperature sampling probe, temp‑humidity module, wireless transmitter(1000‑3000 m), GPRS remote‑transmission |
Remark: Measuring‑ranges and sensor combinations are fully customizable. Please contact our sales for special‑project requirements.
Manufacturer Quality & Reliability
Every Detail Matters. Every Product Deserves Care.
At Oceanus, quality is considered throughout the manufacturing process. From component inspection and product assembly to performance verification and final inspection, we focus on every detail to ensure our products meet the applicable quality requirements before delivery.

Product Inspection → Product Aging Test → Calibration & Performance Verification → Final Inspection Before Delivery
Before shipment, products are checked for appearance, accessories, packaging and order-specific requirements to ensure delivery readiness.
Inquiry Section
Get Custom‑made Quotation For Your Application
Please tell us target‑gas species, measuring‑range, required optional accessories and your field‑working‑conditions. Our team will recommend suitable sensor‑configuration for your spot‑testing scenarios.
Email: info@china-oceanus.com
Telephone: +86 0371 60998169
Mobile/Whatsapp: +86 15981942832
Mobile/Whatsapp: +86 13673683950